Atlas Copco genuine 1089 0574 70 temperature sensors deliver precision thermal monitoring and safety trip protection for industrial rotary screw air compressors. Installed directly at high-temperature monitoring points such as the compression element discharge port and oil injection lines, this sensor safeguards critical machinery against thermal runaway.
The sensor continuously detects operating temperatures and transmits calibrated analog electrical signals to the central Elektronikon microprocessor control module. In rotary screw compressors, compression heat must be continuously absorbed by injected lubricant, making real-time discharge temperature tracking vital for machine survival.
Using an unverified third-party sensor with uncalibrated signal curves leads to false high-temperature shutdown alarms or delayed safety tripping during genuine cooling failures. Genuine Atlas Copco sensors preserve the accuracy of automated thermal protection and controller safety logic.
| Part Number | 1089057470 (1089 0574 70) |
|---|---|
| Product Type | Temperature Sensor |
| Application | Industrial rotary screw air compressors |
| Monitoring Points | Compression element discharge port, oil injection lines |
| Signal Output | Calibrated analog signal to Elektronikon control module |
| Probe Material | Stainless steel / corrosion-resistant metallic sheath |
| Electrical Protection | High electrical isolation, shielded wiring terminals |
| Mounting | Precision-machined threads with dedicated sealing face |
| Packaging | Static-shielded, moisture-resistant individual packaging |
As one of the most professional Atlas Copco suppliers from China, we have focused on 100% genuine Atlas Copco products for more than 19 years. Our professional engineers provide 24-hour technical support and on-site service. We operate a warehouse of over 4,000 square meters with 80% of parts in stock for quick delivery. First-hand sourcing, competitive pricing, and a dedicated service team make us a trusted Atlas Copco supplier.
Resistance drift causes false high-temperature nuisance trips or under-reports actual element discharge heat, risking catastrophic rotor seizure.
Using genuine sealing washers, avoiding loose thread tape, and applying proper torque to the probe prevents oil mist leaks without stripping threads.
Generic sensors with mismatched resistance curves produce inaccurate temperature readings that disrupt automated thermal protection and controller safety logic.
Contact Us at Any Time